PQView 4.26 is Now Available to Download

We are pleased to announce that the latest version of PQView 4 and related components has been released and is available for download here.

The highlights we are most excited to share include:

    • Able to Query ComputerID and License Status from Admin Service – Even if License is Invalid.
    • PQube3 Data Handler now supports Multiple Circuits with both Single and Dual Voltage.
    • SATEC Data Handler can now download Data Logs Stored in Device Memory.
    • Additional Data Handler fixes and improvements for SATEC, PQDIF, SEL, PQube, IEC61850. See Release Notes for Details.
    • Added Option to Reset User Preferences to System Defaults in User Settings and Admin Website.

Click here to download PQView 4.26.00 and associated documentation.

Regards,

The Electrotek Team

 

Release Notes
Version:4.26
Date: 2025.10

[Core]

  • [FEATURE] PQV-2713: PQDIF Observation Mapper: Dynamic Mapping using ChannelParser implemented
  • [FEATURE] PQV-2705: PQDR XSLX Excel Document Output Format Implemented
  • [FEATURE] PQDR: IS17036:2018 compliance standard support added
  • [FEATURE] PQV-2714: EN50160 and IEEE519 PQDR reports enabled by default
  • [FEATURE] PQV-2705: PQDR Trend and CP Distribution chart components added
  • [FEATURE] PQV-2705: OETC reports add-in library added
  • [FEATURE] PQV-2705: PQDR Worst Performers Charts Multi-Site component implementation
  • [FEATURE] PQV-2705: PQDR Individual harmonics compliance per site/interval table report component implemented
  • [FEATURE] PQV-2705: RVC processing implemented in PQDR event loading and classification pathways
  • [FEATURE] PQV-2705: PQDR Support for cascaded Multi-Site property dependent compliance parameters
  • [FEATURE] PQV-2705: PQDR Event Count By Site Components implemented
  • [FEATURE] PQV-2705: PQDR DISDIP tables (optional) category names added
  • [FEATURE] PQV-2705: PQDR Scatter plot with DISDIP regions component
  • [FEATURE] PQV-1235: Support for multi-databases selection in SQL SDK
  • [FEATURE] SUPPORT-1173: Impedance importer – support for delete line segmentation using “_DBBatchSize” INI property (>0 values cause delete operation to be segmented into batches)
  • [FEATURE] SUPPORT-1173: Support for selecting database operations batch size in impedance loader implemented
  • [FEATURE] SUPPORT-1241: Support for configuring SQL SDK data import preferences using a ProgramData\PQView4\SQL.SDK.INTERFACE.ini
  • [FEATURE] SUPPORT-1173: Impedance importer – support for setting PQView import queries timeout using “_DBQueryTimeout” INI property (>0 values cause property setting)
  • [FEATURE] PQV-2735: PQDR Support for NVE 1557-2025 compliance standard
  • [FIX] PQV-2574: Colombia SSPD report globalization formatting issue fix
  • [FIX] PQV-2740: Datalog/Event static charts export issue fixed
  • [FIX] PQV-2739: Scheduler interval segmentation by local date instead of UTC; IEEE519 channel map fixes
  • [FIX] PQV-279: PQDR Flagging records include timestamp of last flagged (Vrms) measurement (<= instead of < comparison)
  • [FIX] PQV-2751: “Max Allowed Sample Rates and Start Times Difference (ε) [s]” preference added to FaultPoint (System) preferences: allows ignoring small sampling rate/s
  • [FIX] Added missing Fault and Impedance tables in the PQV3 Update Script
  • [FIX] Create Fault and Impedance tables with full column set and indexes if not exists
  • [FIX] PQV-2723: RMS Event duration calculation improved for multi-segment RMS variations (long events with start and end waveform recordings)
  • [FEATURE] PQV-2714: – PQDR Reports – revised mechanism for default compliance standard loading – regex based default selection implemented allowing “Default” document bypass.
  • [FIX] PQV-817: PQDR Compliance calculator – Nan/Inf values are ignored; Harmonics scaling with fundamental supports different h/fund sample counts.
  • [FIX] SUPPORT-1267: PQWebSDK – multiple site selection for GetSitePropertyValues issue fixed

[Administration Service]

  • [FEATURE] PQV-2770: AdminService/serverid endpoint available without valid license
  • [FIX] SUPPORT-1187: AS API handling of usernames with included domain improved
  • [FIX] SUPPORT-1214. Corrected issue with Logging delegate initialization. On startup temporary unavailability of the Administration Service could result in multiple logging delegates being registered causing a single log message to be printed multiple times.
  • [FIX] Refactored transaction management: removed TransactionScope, added SqlTransaction

[PQWeb]

  • [FIX] PQWEB-1248: Changing databases selection now updates the date range selector to default.
  • [FEATURE] PQWEB-342 : Added option to reset User Preferences to System Defaults in user settings and admin website.
  • [FIX] PQWEB-1259: Long waveforms interactive chart display fixed
  • [FEATURE] PQWEB-1265: PQDR Scheduler page – run report and refresh list functionality added
  • [FIX] SUPPORT-1246: Fixed the error message issue when creating a user.
  • [FIX] SUPPORT-1264: PQWeb RMS Variations Magnitude-Duration charts display issue fixed
  • [FIX] PQWEB-1267: Fixed decimal input issue for utcoffset based on culture-specific formatting
  • [FIX] PQWEB-342: PQWeb boolen and Multi-select preferences filtering and overloading check improved (values resulting in selection identical to defaults are not stored as overloads)
  • [FIX] PQWEB-342: Added double warning for deleting all preferences and fixed user preferences table display.

[PQView Admin Website]

  • [FEATURE] SUPPORT-1045: Added support for sorting and filtering to the users tab and the resource tab and other tables in the Admin Web.

[PQDMS]

  • [FIX] Added additional logging to the SEL Handler to show file import processing.
  • [FIX] Added additional logging to the PQube Handler better identify connection issues. Connection error status is also now passed on to the Instrument Manager for display.
  • [FIX] PQV-2715: Extra time sample handling improved for Metrum PQDIF files.
  • [FIX] PQV-1268 – revisions to PQube3 Dual-Voltage support to search for hard-code labels “Upstream” and “Downstream”.
  • [FEATURE] PQV-2767: Selected sites list is cleared after successful PQDMS Data Remove and Characterize tasks.
  • [FIX] SUPPORT-1261: PQViewDatabaseConnection DH – improved handling of custom PQView channel mapping (auto mapped to target DB channel if exists instead of looking for source definition)
  • [FIX] SUPPORT-1259: Correct a bug with the Multi-circuit changes that prevented part-of-day downloads from running.
  • [FIX] PQV-2745: Revised to ensure the configuration documents are loaded when the Monitor object is loaded and refreshed before a download.
  • [FIX] Corrected download tracking issue that resulted in excessive downloads if PQDIF import is NOT selected in PQube3 handler. Added additional debug logging.
  • [FEATURE] Added multi-circuit support to the PQube3 handler. This includes both single and dual voltage configurations.
  • [FIX] SUPPORT-1203: Corrected uninitialized wire type for disk mode in SEL Data Handler.
  • [FEATURE] PQV-2713: Optional HarmonicOffset added to the Excel/PQDIF ChannelParser mechanism. Janizta CSV and PQube PQDIF (Interharmonic offset issue) maps implementation
  • [INTERNAL] 61850 download cancellation merge.
  • [FIX] PQV-2625: IEC61850 Data Handler supports downloaded COMTRADE/PQDIF files export
  • [FEATURE] 2625: IEC61850 DH support for optional (ECMAScript) regular expression based filename import filtering.
  • [FIX] PQV-2727: PQDIF DH: Improved harmonic data import for observations with harmonic min/avg/max/val formats stored in separate channel instances
  • [FEATURE] PQV-2713: PQDIF Observation Channel Mapper – support for skipping PQDIF channel import by mapping it to a empty string as PQView channel name.
  • [FIX] SUPPORT-1051, SUPPORT-1203. Revised channel name mapping to in SEL Data Handler address issue with harmonic wild card matching of higher order harmonics (e.g., 10, 11, 12, … )
  • [FIX] SUPPORT-1051: SEL Data Handler. EOI LDP values are now decoded as VAL instead of counts. The change allows for the import of Energy values stored in EOI LDPs.
  • [FIX] Improved error reporting in the top-level Instrument::SetProperties() method. Previously saving changes was masking the error reporting. This issue was not part of earlier released; however, the specific version where the problem was introduced is not clear.
  • [FEATURE] SEL now serializes new disk mode options
  • [FEATURE] SEL ini in disk mode can be ignored by turning off ini override
  • [FIX] Waveform data base is now rebuild based on config change or data source/monitor settings are reset/frequency changes
  • [FIX] Disk mode writer now writes PTR/CTR from meter to ini file in connection mode
  • [FIX] Disk mode now scales by PTR/CTR or if in connection mode where “PRI_SCA” is set to yes
  • [FIX] SEL Handler – Rework cbuffer get line to eat more of the line feed characters to handle when linux based files are handed to us(LF character only for new lines)
  • [FEATURE] More ui disk options were added to handle new disk mode imports. These are not serialized yet and will be reset upon DMS reload.
  • [FEATURE] Only filling out UI or specifying a good .ini file is now required for disk import mode. There is no need for SHO_R based files
  • [FEATURE] Disk mode no longer checks valid file names(i.e for iso8601 time base format or anything). The only requirement for LDP or CEV to import is: a good file, or the file ends with .ldp or .cev
  • [FEATURE] Disk/Event parser now gathers more data from file due to the removal of SHO_R dependent use in disk mode.
  • [FIX] PQVIEW SRP – Made iopath::DirectoryGetFiles not be case sensitive when scanning for search pattern when looking for files so users can have names like this: “CEV”, “cev”, “CEv”, “cEV”, etc.
  • [FEATURE] PQV-2721: IEC61850 DH – Enabled pool cancellation during the file processing. File download progress (10kb steps) reported in debug logs.
  • [FIX] SUPPORT-1051 – PQUBE connect function now scans for which pqube version to use by trying all the URLS that we know about instead of only being done in download function.
  • [FIX] SUPPORT-1051 – PQube will no longer log bad connect messages during connect phase if at LEAST ONE url works. The test however will show up in wireshark and its our auto finding mechanism at work.
  • [FIX] SUPPORT-1051 – PQube during connect now logs the proper url used instead of base url which will just appear to be a ip address for easier debugging.
  • [FIX] SUPPORT-1051 – More logging messages to help find issues.
  • [FIX] 61850 Handler – Hooked up cancel call back.
  • [FEATURE] PQV-2720: IEC61850 DH: Datalog reports background processing frequency preference added.
  • [FEATURE] PQV-2720: IEC61850 DH – Added support for exporting downloaded COMTRADE & PQDIF files to a local or network folder.
  • [FEATURE] PQV-2720: IEC61850 DH supports multiple PQDIF device folders separated by “;” separator. Download COMTRADE events flag set to FALSE prevents download regardless of RCDMade bypass setting.
  • [FIX] PQV-2715: Extra time sample handling improved for Metrum PQDIF files.
  • [FEATURE] PQV-2713: PQDIF Observation Mapper: Dynamic Mapping using ChannelParser implemented.
  • [FEATURE] PQV-2710: PQViewExcel DH: support for specifying custom “DecimalSeparator” to the Sheet definition of the FileDefinition configuration document.
  • [FEATURE] PQV-2709: Dynamic column definitions / header row channel info extraction implementation in PQViewExcel DH.
  • [FEATURE] PQV-2709: ChannelInfoExtractor class for channel info extraction from string implementation. PQViewExcel implementation via ColumnDefinition.ChannelMaper property.
  • [FEATURE] Added support for downloading SATEC data log files including the IEC-61000-4-30 profile log.
  • [FEATURE] PQV-2743: Support for matching by PQDIF channel PH, QT and QM in ObservationDefinition mechanism
Share this news item:
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.